§ 154.2201. Vapor control system---general requirements.

265 words·~1 min read·/us/cfr/t33/s§ 154.2201·

A research copy — for the controlling text, always check the official state or federal source. Not legal advice.

(a)Vapor control system
(VCS)design and installation must eliminate potential overpressure and vacuum hazards, sources of ignition, and mechanical damage to the maximum practicable extent. Each remaining hazard source that is not eliminated must be specifically addressed in the protection system design and system operational requirements.
(b)Any pressure, flow, or concentration indication required by this part must provide a remote indicator on the facility where the VCS is controlled, unless the local indicator is clearly visible and readable from the operator's normal position at the VCS control station.
(c)Any condition requiring an alarm as specified in this part must activate an audible and visible alarm where the VCS is controlled.
(d)A mechanism must be developed and used to eliminate any liquid from the VCS.
(e)A liquid knockout vessel must be installed between the facility vapor connection and any vapor-moving device in systems that have the potential for two-phase (vapor/liquid) flow from the barge or the potential for liquid condensate to form as a result of the enrichment process. The liquid knockout vessel must have---
(1)A means to indicate the level of liquid in the device;
(2)A high liquid level sensor that activates an alarm that satisfies the requirements of 33 CFR 154.2100(e); and
(3)A high-high liquid level sensor that closes the remotely operated cargo vapor shutoff valve required by 33 CFR 154.2101(a) and shuts down any vapor-moving device before liquid is carried over to the vapor-moving device. One sensor with two stages may be used to meet this requirement as well as paragraph (e)(2) of this section.
Connections3 cite this · traces to 2
Citation graph
cites case law
§ 154.2201
Vapor control system---general requirements.
Fed. Reg.×2
C.F.R.×1
Cites 2Cited by 3 across 2 sources
★   the supreme law of the land   ★
Don't Tread on Me
E Pluribus Unum — out of many, one

"If you don't know your rights, you don't have any."

Marginalia · a citizen's law index
A research desk, not legal advice. Always read the cited source before relying on a summary.
Questions or an issue? support@self-law.org
disclaimerMarginalia is a research index, not a law firm. Nothing on this site is legal, tax, or financial advice and no attorney–client relationship is formed by using it. Statutes, regulations, and case law change; summaries, search results, AI output, and member posts may be incomplete, out of date, or wrong. Any interpretation drawn from material on this site should be validated by a licensed attorney in your jurisdiction before you act on it.